ENFORCER 295 - Alarm Control Panel*
Model Number: E-295
*Special order item only. Contact SECO-LARM for more details:
5 Separate zone inputs
*Special order item only. Contact SECO-LARM for more details:
5 Separate zone inputs
- N.O. or N.C. (selectable) instant zone with
exit delay - N.C. instant zone with exit delay
- N.C. delay zone with entry and
exit delays - N.O. 24-hour panic zone with no entry and
exit delays - N.C. 24-hour tamper zone instant trigger
no delay
5 Zone shunting switches correspond to the 5 zone inputs. Shunt out any zone that is not working properly to prevent false alarms.
All inputs are super-high-transient protected.
3 Adjustable timers.
All inputs are super-high-transient protected.
3 Adjustable timers.
- Entry delay timer adjustable from 1 sec
to 45 sec. - Exit delay timer adjustable from 1 sec
to 45 sec. - Alarm duration timer adjustable from 3 sec
to 20 min.
9 Status LEDs.
- (LEDs #1-5) Individual zone status
green LEDs - Total zone status green LED. Indicates total zone status of the
five zones - Arm/disarm/shunt status red LED. Indicates if alarm is armed, disarmed, or if a zone has
been shunted - Entry/Exit status yellow LED. Indicates if alarm is in entry or exit
delay mode - Primary power status red LED. Indicates if AC power is on
or off - All 9 status LEDs visible when cabinet
is closed
2 Alert signals for entry and exit delay.
- Exit delay: A pulsed output during
exit delay - Entry delay: A constant output during
entry delay - Patented Automatic Extended Exit Delay (A.E.E.D.): Opening a switch/sensor connected to an exit delay zone before the exit delay elapses automatically extends the exit delay for as long as the switch/sensor
remains open - Fail-safe circuitry: Alarm cannot be armed unless all switches and sensors connected to unshunted zones are in their non-violated state
- Phase-II continual protection: To assure continuous protection, any input that remains triggered after the alarm duration has elapsed will shut down. All other inputs will
remain armed - Multi-remote arm/disarm: Allows for the installation of up to 10 arming/disarming devices
- Arm/disarm report output: Sends 100mA transistor ground signal to indicate alarm is armed
or disarmed - Tamper output: Sends a 100mA transistor ground signal for as long as the tamper zone
is activated - Dry relay contact panic output (C. - N.O.): Relay contacts close when the panic zone
is activated - Positive voltage (3 Amp) relay alarm output: Powers signaling devices like a siren, bell,
dialer, etc. - Works on 16V AC/DC with back-up
battery input - Use with DC adapter or
Class-II transformer - Regulated power supply and recharger
- Heavy-duty, beige-colored steel cabinet: Measures 81/2"x31/8"x117/16"
(215x79x290 mm)
- Detachable front cover of
steel cabinet - 2 tamper switches included: Detects if steel cabinet front cover opened or cabinet removed
from wall